Multilayer Piezo Ring Actuators 1000 Series

Product Description

Features


  • Compact size

  • Accurate positioning in nm

  • High-speed response in ms

  • Large blocking force

  • High energy conversion efficiency, low power consumption and no electromagnetic noise

  • Easy to be controlled by voltage


 

Scope of applications
 

  • R&D and industry

  • Precision mechanics and mechanical engineering

  • Life sciences, Medicine and Biology

  • Nano positioning, Fiber positioning, High-speed switching, Tunable lasers



    Dimension




Specification
 

Model

Dimensions

Nominal displacement

Blocking force

Stiffness

Electrical capacitance

Resonance Frequency

OD/ID/H

[µm@1000V]

[N@1000V]

[N/µm]

[µF]

[kHz]

 [mm]

±10%



±20%

±20%

KLJ10002515301

Φ25/Φ15/30

30

8600

280

3

50

 * Customize on request. 

Product Instruction

Instructions:

The product belongs to the large output, small displacement (relative to the millimeter level) electronic components. Due to the small displacement, the use of the product must pay attention to good contact with the load (preferably rigid connection). Soft connection is easy to make product displacement loss. It is generally not allowed to use no load, and a certain amount of prestress is required.

 

Prestress comparison table (rectangle):

 

Cross Sectional Area

Standard Pressure
[MPa]

Maximum Pressure
[MPa]

Suggested prestress 
[N]

Maximum prestress
[N]

Length[mm]

Width[mm]

5

2.5

15

20

220

300

8

4.5

15

20

510

690

10

5.5

15

20

820

1100

12

5

15

20

1400

1870

9.5

5.5

15

20

700

940

20

15

15

20

2060

2750

13

4

15

20

1800

2400

26

19

15

20

3700

4950

12

3

15

20

1590

2120

25

15

15

20

4710

6280

Using condition:

The product temperature range is -20~120°C, and the ambient humidity is 75%. If the temperature is too high, the product may be damaged or the performance may be degraded. In a high-humidity environment, the insulation resistance of the product may be lowered, which may affect the service life or damage of the product.


Cautions

Cautions:

1. The material of the product is ceramic material and has brittleness. Therefore, when using this product, the contact method should be surface contact. Do not use point contact or line contact. When using this product, the output direction and the axial direction of the device must be consistent. As shown below:

   

 


2. When the product is powered on, it is strictly forbidden to use voltage which is over rated voltage. (Refer to the 5.0 coding rule for the rated voltage.) It is recommended that the input current does not exceed 15A.

3. The output at zero displacement is the maximum output. Conversely, the output at the maximum displacement will be close to infinitely small. It is recommended to select the correct model to meet normal use.

 


Test Method

Test method:

1. The test table must be horizontal and the product must be perpendicular to the table.Test contacts must touch the center of the actuator's end face and must be placed perpendicular to the horizontal table before testing.

2. The power supply must be a DC regulated power.

3. Wiring method: the red wire is connected to the positive pole and the black wire is connected to the negative pole.

4. Specific installation: as shown in the figure below

 


Materials Performance

Materials performance:

Key Technical Index

Unit

Value

Relative dielectric constant εr3T

-

3500±20%

Electromechanical coupling factor  Kp

-

70%

Longitudinal piezoelectric strain coefficient  d33

10-12C/N

≥650

Piezoelectric voltage constant  g33

10-3Vm/N

17

Elastic flexible coefficient  S11E

10-12m2/N

14.3

Elastic flexible coefficient  S33E

10-12m2/N

18.5

Dielectric loss  tgδ

10-3

≤1.5

M quality factor  Qm

-

45

Curie temperature  TC

240



Product Inquiry

Piezoelectric actuator for tuning fork switch

Multilayer Piezo Round Actuators 200 series

Multilayer Piezo Round Actuators 150 series

Multilayer Piezo Special-Shaped Actuators 150 series

Shaped Multilayer Piezo Actuators/ Customization/ Strain Gage Glued Type